11

NVC Series B-Vent

20000194

5. Place the front right log on top of the burner, Use

bottom holes to locate the logs on top of the studs.

6. Place the top logs onto the locator notches.

Ensure

that the logs a

re secure. (Fig. 12)

7. Place ember material. See "Ember Material Place-

ment" section.

NVC36

NVC39

NVC43

Front Left Log

BB6

BC5

BD6

Front Right Log

BB7

BC6

BD7

Rear Log

BE5

BC7

BD8

Top Left Log

BB9

BC8

BD9

Top Right Log

BB10

BC9

BD10

Lava Rock

The lava rock provided with this fireplace must be
placed on the firebox base on either side of the burner
assembly. Do not place lava rock in combustion pan.

Under no circumstances should this lava
rock be placed on any part of the burner
assembly.

Ember Material Placement

Separate the ember material into small pieces, roughly
1/2" in diameter, and place onto the burner in front of
the front logs. Do NOT pack down, leave in fluffy, loose
condition for more realistic ember effect.

Flame Adjustment

For fireplaces equipped with HI/LO valves, flame
adjustment is accomplished by rotating the HI/LO
adjustment knob located near the center fo the gas
control. (Fig. 13 or 14)

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

Fig. 13 Flame adjustment knob for Honeywell valve.

HV102

Turn

counterclockwise

to increase

flame height

Turn clockwise

to decrease

flame height

IH

L O

Fig. 14 Flame adjustment knob for SIT valve.

HV116

Fig. 12 Log locations.

BE5 Log Rear

BB9 Log Top Left

BB10 Log Top Right

BB6
Log Front
Left

BB7
Log
Front
Rigth

NVC36

BD8 Log Rear

BD9 Log Top Left

BD10 Log Top Right

BD6
Log Front
Left

BD7
Log
Front
Right

NVC43

BC7
Log
Rear

BC8 Log Top Left

BC9
Log Top Right

BC5 Log
Front
Left

BC6
Log Front
Right

NVC39

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the ,
pictorials illustrated below. (Figs. 15 or 16) If the flame
patterns appear abnormal contact a qualified service
provider for service and adjustment.

Fig. 15 Proper pilot flame height.

FP392/585