NVC Series B-Vent

20000194

Clearance to Combustibles

Appliances

Top ........................................................... 0” (0mm)
Bottom ..................................................... 0” (0mm)
Side ......................................................... 0” (0mm)
Back ......................................................... 0” (0mm)
Perpendicular Sidewall ............................ 0” (0mm)
Top of unit to ceiling ........................... 36” (914mm)
Front of unit to combustibles ............. 36” (914mm)

Venting

B-Vent .................................................... 1” (25mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.

For the correct mounting height and widths refer to
Figures 2a and 2b and the Mantel Chart below.

The distances and reference points are not affected by
the fitting of a bay window front trim kit.

Noncombustible mantels and legs may be installed at
any height and width around the appliance.

When using a paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.

A

B

C

D

E

V

W

X

Y

Z

Fireplace

Ref.

Mantel

Ref.

Mantel From Top

Shelf Depth

of Comb. Chamber

V

10" (254mm)

A

19

¹⁄₂

" (495mm)

W

8" (203mm)

B

17

¹⁄₂

" (444mm)

X

6" (152mm)

C

15

¹⁄₂

" (394mm)

Y

4" (101mm)

D

13

¹⁄₂

" (343mm)

Z

2" ( 51mm)

E

11

¹⁄₂

" (292mm)

Fig. 2a Mantel clearances.

Side View

CFM146

Top of
Combustion Chamber

Bottom of Door Trim

Top Louvre Assembly

J

F

G

H

I

Mantel
Leg

Ref.

Mantel

Ref.

Mantel Leg From Side

Leg Depth

of Comb. Opening

F

10" (254mm)

K

12" (305mm)

G

8" (203mm)

L

10" (254mm)

H

6" (152mm)

M

8" (203mm)

I

4" (101mm)

N

6" (152mm)

J

2" ( 51mm)

O

4" (101mm)

O

N

M

L

K

CFM164

CFM170

Fig. 2b Combustible mantel leg minimum installation.

Side of
Combustion Chamber

Black
Surround
Face

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.

Cold climate installation recommendation: When

installing this unit against a noninsulated
exterior wall or chase, it is mandatory
that the outer walls be insulated to
conform to applicable insulation codes.