TROUBLESHOOTING

Problem

Possible Cause

Solution

Compressor will not run

Loss of power or overheating

No electrical power

Blown shop/house fuse

Shop/house breaker open

Thermal overload open

Pressure switch bad

Tank is full of air

Check for proper use of extension

cord

Check to be sure unit is plugged in

Check fuse/breaker or motor over­

load

Replace shop/house blown fuse

Reset shop/house breaker, determin­

ing why problem happened

Motor will restart when cool

Replace pressure switch

Compressor will turn on when tank

pressure drops to cut-in pressure

Motor hums but cannot run or runs

slowly

Low voltage

Wrong gauge wire or length of exten­

sion cord

Shorted or open motor winding

Defective check valve or unloader

Check with voltmeter

Check for proper gauge wire and

cord length

Take compressor to service center

Take compressor to service center

Fuses blow/circuit breaker trips

repeatedly

Incorrect size fuse, circuit overload

Wrong gauge wire or length of exten­

sion cord

Defective check valve or under loader

Check for proper fuse, use time­
delay fuse, disconnect other electri­

cal appliances from circuit or operate
compressor on its own branch circuit

Check for proper gauge wire and

cord length

Take compressor to service center

Thermal overload protector cuts out

repeatedly

Low voltage

Lack of proper ventilation/room tem­

perature too high

Wrong gauge wire or length of exten­

sion cord

Check with voltmeter

Move compressor to well-ventilated

area

Check for proper gauge wire and

cord length

Air receiver pressure drops when

compressor shuts off

Loose connections (fittings, tubing,

etc.)

Loose drain valve

Check valve leaking

Check all connections with soap and

water solution and tighten

Tighten drain valve

Take compressor to service center

^ DANGER:

Do not disassemble check valve

with air in tank — bleed tank.

Excessive moisture in discharge air

Excessive water in air tank

High humidity

Drain tank

Move to area of less humidity; use air

line filter

Compressor runs continuously

Defective pressure switch

Excessive air usage

Take compressor to service center

Decrease air usage; compressor not
large enough for tool’s requirement

Compressor vibrates

Loose mounting bolts

Tighten mounting bolts

Air output lower than normal

Broken inlet valves

Connections leaking

Take compressor to service center

Tighten connections