Bolens 132-698A User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

■'•"vr ''ll

Large

Open^

Filling

Adapter

' f; . ,■

Upper Level

Marked on

Front of

Battery

FIGURE 5.

I WARNING {

Battery contains sulfuric acid. Refer to warning on
page 4. Antidote: EXTERNAL—Flush with water.
INTERNAL—Drink large quantities of water or

milk. Follow with milk of magnesia, beaten egg or

vegetable oil. Seek prompt medical attention.

EYES: Flush with cool water for at least 15
minutes, then seek immediate medical attention.

Since batteries produce explosive gases, keep all

lighted materials (cigarettes, lighters, matches,
etc.) away. Be sure to charge battery only in well-

ventilated areas.

KEEP BATTERIES

OUT OF THE REACH OF CHILDREN!

5. Lay acid package down, with “push in” facing

up. Using thumb, push in small perforated tab

at dot on front of package. Tear down large tab
to solid line, exposing hose. Do not use any
sharp object to open acid package.

6. Pull out hose from package and hold upright.

Squeeze hose forcing all acid back into

package. Cut off tip of hose and insert filling

— adapter. See figure 5.

7. Fill each cell to upper level marked on front of

battery. Replace fill caps on battery. See

figure 5.

8

.

9.

Allow battery to sit for 20 to 30 minutes. Add
additional acid, if necessary, to bring it up to
the proper level.

The battery can be charged after the 20

minutes sitting period. SLOW CHARGE THE

BATTERY (DO NOT FAST CHARGE) at a max­

imum bench rate of 1.4 amperes until the

specific gravity reading is 1.260-1.280. Charge
for a minimum of 2 hours and a maximum of 8
hours.

HI^NOTE

Charging rate after battery has been
put into operation: The battery is to
be charged for a period of 14-16
hours. NO LONGER THAN 30
HOURS.

A

CAUTION

After battery has been in service,
add only distilled water. DO NOT
ADD ACID.

FIGURE 6.

NOTE

This engine is equipped with a dual

circuit alternator. The current for
the battery charger alternator is un­
regulated and is rated at 3 amperes

at 3600 r.p.m. During normal opera­
tion, it is only necessary to charge

the battery:

1. When it is activated for the first

time.

2. Before winter storage.
3. Before using the lawn tractor

after winter storage.

INSTALLING THE BATTERY

— 1. Place gear shift lever in the “neutral” posi­

tion. Unscrew the gear shift knob. See figure
6

.