Chapter 5 Input/Output Interfaces

Compaq Deskpro 4000N and 4000S Personal Computers

First Edition – September 1997

5-26

FIFO Register, I/O Port 7F8h (ECP Mode Only)

While in ECP/forward mode, this location is used for filling the 16-byte FIFO with data bytes.
Reads have no effect (except when used in Test mode). While in ECP/backward mode, reads
yield data bytes from the FIFO.

Configuration Register A, I/O Port 7F8h (ECP Mode Only)

A read of this location yields 10h, while writes have no effect.

Configuration Register B, I/O Port 7F9h (ECP Mode, Read Only)

A read of this location yields the status defined as follows:

Bit

Function

7

Reserved (always 0)

6

Status of Selected IRQ

n.

5,4

Selected IRQ Indicator:
00 = IRQ7
11 = IRQ5
All other values invalid.

3

Reserved (always 1)

2..0

Reserved (always 000)

Extended Control Register B, I/O Port 7FAh (ECP ModeOnly)

This register defines the ECP mode functions.

Bit

Function

7..5

ECP Submode Select:
000 = Standard forward mode (37Ah <5> forced to 0). Writes are
controlled by software and FIFO is reset.
001 = PS/2 mode. Reads and writes are software controlled and
FIFO is reset.
010 = Parallel Port FIFO forward mode (37Ah <5> forced to 0). Writes are
hardware controlled.
011 = ECP FIFO mode. Direction determined by 37Ah, <5>. Reads and
writes are hardware controlled.

4

ECP Interrupt Mask:
0 = Interrupt is generated on ERR- assertion.
1 = Interrupt is inhibited.

3

ECP DMA Enable/Disable.
0 = Disabled
1 = Enabled

2

ECP Interrupt Generation with DMA
0 = Enabled
1 = Disabled

1

FIFO Full Status (Read Only)
0 = Not full (at least 1 empty byte
1 = Full

0

FIFO Empty Status (Read Only)
0 = Not empty (contains at least 1 byte)
1 = Empty

Advertising