INFUSION TIME - OPTIONAL

INFUSION TIME

## SECONDS

Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water
into the grinds during the Pre-Infusion process.
SOAK TIME – OPTIONAL

SOAK TIME

## SECONDS

Description – The Soak Time is the amount of time that the system will wait between the end of the hot
water infusion period and the beginning of brewing.
PULSE BREW - OPTIONAL

PULSE BREW

ON/OFF

Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing
(pulsing) hot water.
PULSE ON TIME -OPTIONAL

PULSE ON TIME

## SECONDS

Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot
water during a Brew Cycle.
PULSE OFF TIME -OPTIONAL

PULSE OFF TIME

## SECONDS

Description – The Pulse OFF Time is the amount of time that the system will wait between hot water
dispenses during a Brew Cycle.
DRIP TIME

DRIP TIME

### SECONDS

Description – The Drip Time is the amount of time that the system will wait after the completion of the
hot water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining
in the funnel to drain out.
WATER TEMPERATURE

WATER TEMP

### °F

Description – The Water Temperature is the required (set point) temperature of the water in the reservoir
tank.
TEMPERATURE SENSOR CALIBRATION

TEMP SENSOR CAL

ARE YOU SURE ?

Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed
water temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed
temperature to match the reference thermometer. Depress one of the
[Hidden] Keys when the calibration is complete.

TEMP SENSOR CAL

### °F

LOCKOUT TEMPERATURE

LOCKOUT TEMP

### °F

Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow
a Brew Cycle to begin unless the water is above the Lockout Temperature.
SLEEP TIMER

SLEEP TIMER

ON/OFF

Description – The Sleep Timer feature automatically reduces the water temperature to three degrees
above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.
WARMER POWER

WARMER POWER

### %

Description – The Warmer Power feature allows the user to reduce the actual heating power of the
warmers. The percentage displayed is percentage of maximum power.