INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE.
SAFETY DISTANCES
Side walls:
Wdodbuming sauna staves are regarded as fireplaces having scorching surfaces, fn our stoves,
Die surface temperature will not exceed 350 and the following safety distances should be
observed when using them:
tnflammabia structural elements such as wooden walls, sauna
seats etc.
1. Minimum distance between the vertical surfaces of the stove
and any unprotected wooden structural element: 20 inches.
(Figure 1)
Figure 1
However, the safety distance mentioned in item
1 can be decreased to minimum 10 inches provided
a single light protection is used. This kind of single
light protection can be constructed either by using a
minimum
З inches thick incombuistibie cement plate
reinforced with fiber, or by fastening an at least
20 gauge sheet metal plate densely enough to the wall.
A minimum 1-1/4" space must be left between
the protective plate and the wooden surface to be
protedted. This can be don© by using spacers
as intern^ediate supports
(Figure 2)
3.
The safety distance mentioned on item 1 can be
furtherdecreased
to
minimum
5
inches
provided
a
double
protection
Is
used.
The
double
protection
can be constrvcted using two plates described in
item 2, in addition to which an at least 1-1/4" space
be left between the wall and the plates.
(Figure 3)
Figure
2
• AncJior MOW
sif apaco
"20 OÜUQÜ fiticct mowt