INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE.

SAFETY DISTANCES

Side walls:

Wdodbuming sauna staves are regarded as fireplaces having scorching surfaces, fn our stoves,

Die surface temperature will not exceed 350 and the following safety distances should be

observed when using them:

tnflammabia structural elements such as wooden walls, sauna
seats etc.

1. Minimum distance between the vertical surfaces of the stove

and any unprotected wooden structural element: 20 inches.

(Figure 1)

Figure 1

However, the safety distance mentioned in item

1 can be decreased to minimum 10 inches provided

a single light protection is used. This kind of single
light protection can be constructed either by using a

minimum

З inches thick incombuistibie cement plate

reinforced with fiber, or by fastening an at least
20 gauge sheet metal plate densely enough to the wall.

A minimum 1-1/4" space must be left between

the protective plate and the wooden surface to be

protedted. This can be don© by using spacers

as intern^ediate supports

(Figure 2)

3.

The safety distance mentioned on item 1 can be

furtherdecreased

to

minimum

5

inches

provided

a

double

protection

Is

used.

The

double

protection

can be constrvcted using two plates described in
item 2, in addition to which an at least 1-1/4" space
be left between the wall and the plates.

(Figure 3)

Figure

2

• AncJior MOW

sif apaco

"20 OÜUQÜ fiticct mowt

Advertising