LEF-5 one PanTilt entry long distance application

MYW-P1L connects one PanTilt door to LEF-(5,10,10S) with MYH-CU video-monitor(s).

MYW-P1L

MYH-CU

Wiring

Single pair cable to PanTilt door station. It is also suggested to specify the same type for wiring to monitor(s), which is
separated from LEF audio wiring.

Wiring distance MYW-BA to PanTilt door station

Diameter

1.0mm

1.2mm

AWG

18AWG

16AWG

Distance

200m

300m

Distance

650’

980’

MYW-BA to MYW-P1L monitor(s)

Diameter

1.0 or 1.2mm

AWG

18or16AWG

Distance

50m

Distance

165’

One power supply PS-18D(18C) suffices for one MYW-BA connected MYW-P1L system with one MYH-CU monitor.
Max. distance from MYW-P1L to a video monitor(farthest) is 75m w/1.0mm dia. (245’ w/18AWG).
Refer to the MYW-P1L Manual for non-MYW-BA used system examples.