Installing, Notice – Desa PROPANE GAS LOG HEATER User Manual

Page 10

Advertising
background image

10

102318

Heat Resistant
Material

(A)

INSTALLING

Continued

NOTICE

You may use this heater as a vented product. If
so, you must always run heater with chimney flue
damper open. If running heater with damper open,
non-combustible material above fireplace open-
ing is not needed. Go to

Installing Damper Clamp

Accessory for Vented Operation, page 13.

Minimum Non Combustible Material Clearances

If Not Using Mantel
Note:

If using a mantel, go to page 11. If not using a mantel, follow the information

on this page.

You must have non combustible material(s) above the fireplace opening. Non
combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch
thick. With sheet metal, you must have non combustible material behind it. Non
combustible material must extend at least 8" up. If non combustible material is less
than 12", you must install the fireplace hood accessory. See chart below and Figure
5 for minimum clearances.

IMPORTANT:

If you cannot meet these minimum clearances, you must operate

heater with chimney flue damper open. Go to Installing Damper Clamp Accessory
for Vented Operation,
page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Non combustible material OK.

Between 8" and 12"

Istall fireplace hood acessory (GA6050
or GA6052, see

Accessories, page 31).

Less than 8"

Non combustible material must be
extended to at least 8". See

Between 8"

and 12", above. If you cannot extend
material, you must operate heater with
flue damper open.

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace