Inspecting burners, Warning, Notice – Desa PROPANE GAS LOG HEATER User Manual

Page 24

Advertising
background image

24

102318

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

Figure 24 - Correct Pilot

Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot

Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 25

• turn heater off (see To Turn Off Gas to Appliance, page 23)
• see Troubleshooting, pages 25 through 28

WARNING ICON

G 001

WARNING

If yellow tipping occurs, your heater could produce increased levels
of carbon monoxide. If front burner flame pattern shows yellow
tipping, follow instructions at bottom of this page. Yellow flame on rear
burner is normal.

FRONT BURNER FLAME PATTERN

Figure 26 shows correct front burner flame pattern. Figure 27 shows incorrect front
burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of
blue flame.

If front burner flame pattern is incorrect, as shown in Figure 27

• turn heater off (see To Turn Off Gas to Appliance, page 23)
• see Troubleshooting, pages 25 through 28

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine
particles are burned by heater, causing brief patches of orange flame.

CORRECT FLAME PATTERN AT HIGH POSITION

INCORRECT FLAME PATTERN AT HIGH POSITION

Figure 27 - Incorrect Front Burner Flame Pattern

Figure 26 - Correct Front Burner Flame Pattern

Yellow
Tipping
At Top
of Blue
Flame

Advertising