Technical service, Service hints, Specifications – Desa PROPANE GAS LOG HEATER User Manual

Page 29

Advertising
background image

29

102318

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).

SPECIFICATIONS

24" MODEL

Btu (Variable)

20,000/33,000

Type Gas

Propane Only

Ignition

Piezo

Manifold Pressure

7.9" W.C.

Inlet Gas
Pressure (in. of water)

Maximum

14"

Minimum*

11"

Shipping Weight

38 lbs.

* For the purpose of input adjustment

When gas pressure is too low

• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.