For the Fitter

2.4 Installation Site

A

The unit may not

- be operated in rooms where there is a risk of fire or explosion due to chemicals, dust, gases or

fumes;

- be operated in the immediate vicinity of pipes or containers which carry or contain inflammable

or explosive substances;

- be operated when the minimum distances from adjacent object surfaces are not kept.

In rooms in which exhaust fumes, oil and petrol smells occur, the unpleasant smell may linger and

could possibly cause soiling.

Installation wall

Check whether a wall of sufficient stability is available for fastening the unit.

If no suitable fastening wall is available, the unit must be fixed to the floor (screwed directly to the

floor or to another floor console [special accessory]).

Floors

The standing surface of the unit must be level and sufficiently stable so that the housing is not

deformed.
A temperature resistance of the fastening wail of at least 85 X and of the floor of at least 80 X

must be ensured. The units can be placed on any conventional floor but changes may occur in the

rail area on PVC, parquet and long pile carpeted floors under the influence of pressure and tem­
perature. In this case heat-resistant underlay tiles must be used (to be provided on site).

2.5 Unit Installation (fig. 3-14)

The storage heater must be secured by a wall or floor fixture (fig. 8) to meet the VDE standing

safety requirement.

The screws and plugs necessary for fixing the unit are not included in delivery. They must be

selected and provided by a qualified fitter depending on the respective wall material.

Wall fastening

There is a hole in the unit rear wall in the vicinity of the switching area through which a suitable
screw can be inserted for fixing to a sufficiently stable wall (fig. 8).

Before fixing the unit, make sure that the permissible minimum distances from adjacent objects
are kept.

Floor fastening

The unit is fixed to the floor by screwing the bottom of the unit to the floor through 4 9 mm holes

(see "Technical Data", page 9 for dimensions).

This type of fixture is only possible with the air outlet and inlet grilles and the fan drawer removed.

x:.

i/i

O )

c:

27