6 first-time operation, 1 function test, 2 charging – AEG WSP 7010 User Manual

Page 16: 7 repair, conversion of unit, 1 conversion of the unit, 8 transfer, Symbols of the rating plate

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

For the Fitter

2.6 First-time Operation

2.6.1 Function Test

Check the function of the fan for the storage unit by switching on the room temperature

regulator.

2.6.2 Charging

The units can be started without initial heating up after the function test. Charging takes place

either manually with the adjuster of the mechanical charging control unit or automatically with

the available Elfamatic charging control unit.

During initial charging, the charging in kWh must be determined and compared with the
maximum permissible charging from the cold state specified in the "Technical Data". The
determined charging may not exceed the maximum permissible charging from the cold state.

During initial charging, a smell may be produced, the room should therefore be adequately aired

Xl\ {1.5 times air change, e.g. tilted windows). Initial charging in the bedroom should not take place

/ • \ when sleeping in it if possible.

2.7 Repair, Conversion of Unit

Proceed according to these installation instructions as for the initial installation for re-installation

of a unit which has been dismantled for repairs or which was in operation somewhere else.

In these cases the following must be paid special attention: Parts of the thermal insulation at
which there are visible signs or damage or change which could impair the safety must be replaced
by new parts. The insulation must be tested and the rated consumption measured before commis­
sioning.

2.7.1 Conversion of the Unit

The instructions enclosed with the respective fitting set are applicable for conversions, additions

and installations.

2.8 Transfer

Explain the functions of the unit to the user. Draw his attention to the safety instructions in
particular.
Hand over the operating and installation instructions to the user.

O)

l

S

AEG

WSP 7010

357 kg

E-No. 956 042 710

F-No, 2(^200504

-E№

1/N/PE AC 230V 50Hz

a

1,5 kW

A

26 W

-

C € Made in Germany

Symbols of the rating plate

(Example WSP 7010)

Q

Total weight

)

Charging

Discharging

-EMT Supplementary heater

A