What to do when ... ?

the storage heater

does not get hot

the storage heater

housing should get
extraordinarily
hot even in mild
weather

For the User

Check whether...
... the selector knob is set to

position 3.

... the corresponding fuses in

your fuse box are defective or

the FI switch has switched off.

Eliminate the cause!

If the following day the

storage heaters have still not

heated up, call a specialist.

Check whether...
... the fan can be switched on

with the room temperature

regulator.
If not, call a specialist

... the fluff screen in the air inlet

grille is blocked.

Eliminate cause as described
in section 1.4.1 !

For the specialist

Check whether...
... the control of the heating

element contactor is OK.

... there is a voltage at terminals

L1/L2/L3.

... whether the safety temperature

limiter (FI) has triggered.

"CUC"

A

H I M

LH

^ ^ ^ i

(J. r t' tr/C- ii'.ii'C-

Check whether...
... the room temperature

regulator has switched on and

voltage is applied at terminal

LE.

... the fans are turning.
... the safety temperature

regulator "(N5, see page 3,

fig. 1) in the air outlet has
switched off.

... the control signal Z1 of the

charging control unit is applied
at terminal Al/Zl in the

storage heater.