POSSIBLE cAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnected

or improperly connected

4. Burners will not come on in

remote position

1. Manifold pressure is too low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

3. Residues from manufacturing

processes and logs curing

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. Improper log placement

2. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. Burner flame holes blocked

REMEDY

1. Clean burner (see Cleaning

and Maintenance, page 18)

or replace burner orifice

2. Contact local propane/LP or

natural gas company

3. Reconnect leads (see Wiring

Diagram, page 26)

4. Replace battery in transmitter

and hand-held remote

1. Contact local propane/LP or

natural gas company

2. Clean burner (see Cleaning

and Maintenance, page 18)

or replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 18)

or replace burner orifice

2. Replace damaged burner

3. Replace gas control

1. Check burner for dirt and debris.

If found, clean burner (see Clean-

ing and Maintenance, page 18)

2. Replace gas control

3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

1. Turn control knob to LO position

and let warm up for a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local propane/

LP or natural gas company

3. Observe minimum installation

clearances (see page 8)

4. Clean burner (see Cleaning

and Maintenance, page 18)

or replace burner orifice

1. Properly locate logs (see In-

stalling Gas Log Into Stove,

page 11)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burner inlet.

Periodically repeat as needed

4. Remove blockage or replace

burner

OBSERVED PROBLEM

Burner does not light after

ODS/pilot is lit

Delayed ignition burner

Burner backfiring during com-

bustion

Slight smoke or odor during

initial operation

Moisture/condensation noticed

on windows

Heater produces a whistling

noise when burner is lit

Dark residue on logs or inside

of fireplace

TROUBLESHOOTING

Continued

Advertising