Specifications, Replacement parts, Service hints – Desa SVYD18PRA User Manual

Page 26: Technical service, Wiring diagram

Advertising
background image

www.desatech.com

113084-01E

6

WIRING DIAGRAM

Note:

For proper operation of optional accessories,

the wires from the switch to the control must be

connected exactly as shown.

AUTO

OFF

ON

Thermopile

SPECIFICATIONS

SVYD18PRA

• Rating: 21,000/31,000 Btu (Variable)

• Gas Type: Propane/LP

• Ignition: Piezo

• Pressure Manifold: 8" WC

• Inlet Gas Pressure (in. of water):

Maximum - 14", Minimum - 11"

• Shipping Weight: 28 lbs.
SVYD18NRA

• Rating: 24,000/35,000 Btu (Variable)

• Gas Type: Natural

• Ignition: Piezo

• Pressure Manifold: 3.5" WC

• Inlet Gas Pressure (in. of water):

Maximum - 10.5", Minimum - 5"

• Shipping Weight: 28 lbs.

*

For input adjustment

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they can’t supply original replacement part(s),

call DESA Heating Products’ Technical Service

Department at 1-866-672-6040. When calling

DESA Heating Products, have ready

• your name and address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

can’t supply original replacement part(s), call

DESA Heating Products at 1-866-672-6040 for

referral information. When calling DESA Heating

Products, have ready

• model number of your heater

• the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low (propane/LP

only)

You may feel your gas pressure is too low. If so, con-

tact your local propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Products’ Technical Service Department at

1-866-672-6040. When calling, please have your

model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ techni-

cal services web site at

www.desatech.com

.