3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use

any phone in your building

• immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions

• if you cannot reach your gas supplier, call

the fire department

4. This heater shall not be installed in a bedroom

or bathroom.

5. Do not use this stove as a wood burning fireplace.

Use only model SVYD18PRA/NRA series vent-

free gas log heater for VCIS(*), PVCIS(*) and

VH(*)A series cast iron stove models.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite or rock wool. Using

these added items can cause sooting.

7. This log heater is designed to be smokeless. If

logs ever appear to smoke, turn off heater and

call a qualified service person. Note: During

initial operation, slight smoking could occur

due to log curing and heater burning manu-

facturing residues.

8. To prevent the creation of soot, follow the

instructions in Cleaning and Maintenance,

page 18.

9. Before using furniture polish, wax, carpet

cleaners or similar products, turn heater off.

If heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

10. This heater needs fresh, outside air ventilation

to run properly. This heater has an Oxygen

Depletion Sensing (ODS) safety shutoff system.

The ODS shuts down the heater if not enough

fresh air is available. See Air for Combustion

and Ventilation, page 5. If heater keeps shutting

off, see Troubleshooting, page 19.

11. Do not run heater

• where flammable liquids or vapors are used

or stored

• under dusty conditions

12. Do not use this stove to cook food or burn

paper or other objects.

13. Do not use heater if any part has been exposed

to or under water. Immediately call a qualified

service technician to inspect the room heater

and to replace any part of the control system and

any gas control which has been under water.

SAFETY INFORMATION

Continued

14. Do not operate heater if any log is broken. Do

not operate heater if a log is chipped (dime-

sized or larger).

15. Turn heater off and let cool before servicing.

Only a qualified service person should service

and repair heater.

16. Operating heater above elevations of 4,500

feet could cause pilot outage.

17. To prevent performance problems, the use of a

propane/LP tank of less than 100 lb. capacity

(propane/LP units only).

18. Provide adequate clearances around air

openings.

PRODUCT

IDENTIFICATION

ON

OFF

REMOTE

PIL

OT

O

F

F

O

N

LO

HI

Figure 1 - Typical Stove Cabinet Model with

Gas Log Heater (Shown is Oxford™ Model

with Model SVYD18PRA/NRA Heater)

Stove
Body

Stove Door
(Shown in the
open position)

Piezo
Ignitor

Control
Knob

One Piece
Log Set Inside
Stove Cavity

Gas Log Heater
Base Assembly

Flame
Adjustment
Knob

Optional
Remote
Selector
Switch

Advertising
This manual is related to the following products: