INSTALLATION

NOTIcE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install fire-

place. Follow all local codes.

WARNING: Never install the

heater

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 42" from

the front, top or sides of the

heater

• in high traffic areas

• in windy or drafty areas

cAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air

for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use only the correct type of gas (natural or pro-

pane/LP). If your gas supply is not the correct gas

type, do not install heater. Call dealer where you

bought heater for proper type heater.

WARNING: This appliance

is equipped for natural or pro-

pane/LP gas. Field conversion

is not permitted.

cLEARANcES TO cOMBUSTIBLES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining side

and back walls.

Carefully follow the instructions below. This stove

is a freestanding unit designed to set directly on the

floor. IMPORTANT: You must maintain minimum

wall and ceiling clearances during installation. The

minimum clearances are shown in Figure 4, page 9.

Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances
(see Figure 4, page 9)

A. Clearances from outermost point of stove top

to any combustible side wall should not be

less than 12".

B. Clearances from outermost point of stove top

to any combustible back wall should not be less

than 6" (includes corner installations).

C. Clearances from the stove top to the ceiling

should not be less than 48".