Service procedures, Continued – Desa D20H User Manual

Page 10

Advertising
background image

10

105843

PORTABLE FORCED AIR HEATERS

D20H, D30H AND D44H MODELS

AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters

PUMP PRESSURE
ADJUSTMENT

1.

Remove pressure gauge plug from filter
end cover.

2.

Install accessory pressure gauge (part
number HA1180).

3.

Start heater (see Operation, page 5).
Allow motor to reach full speed.

4.

Adjust pressure. Turn relief valve to
right to increase pressure. Turn relief
valve to left to decrease pressure. See
specifications below for correct pres-
sure for each model.

5.

Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.

Figure 13 - Air Output, Air Intake, and Lint Filters, D20H Model

Figure 15 - Pressure Gauge Plug Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 16 - Adjusting Pump Pressure

Pump
Pressure

Model

(PSI/Bar)

D20H

4.7/0.324

D30H

4.9/0.338

D44H

5.5/0.380

(D20H Model Shown)

Relief
Valve

SERVICE
PROCEDURES

Continued

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Air Intake Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, D30H and D44H Models

Fan Guard