105843

OWNER’S MANUAL

OPERATION

WARNING: Review and un-

derstand the warnings in the
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.

TO START HEATER

1.

Follow all ventilation and safety infor-
mation.

2.

Fill fuel tank with kerosene or No. 1
fuel oil.

3.

Attach fuel cap.

4.

Plug power cord of heater into standard
230 volt/50 hertz, grounded (earthed)
outlet. Use an extension cord if needed.
Use only a three-prong, grounded
(earthed) extension cord.

Figure 5 - ON/OFF Switch, D20H Model

Figure 6 - ON/OFF Switch, D30H and
D44H Models

THEORY OF
OPERATION

The Fuel System

The air pump forces air through the air line.
The air is then pushed through the burner
head nozzle. This air causes fuel to lift from
the tank. A fine mist of fuel is sprayed into
the combustion chamber.

The Air System

The motor turns the fan. The fan pushes air
into and around the combustion chamber.
This air is heated and provides a stream of
clean, hot air.

The Ignition System

The ignition control assembly provides
power to the ignitor. This ignites the fuel/air
mixture in the combustion chamber.

The Flame-Out Control System

This system causes the heater to shut down
if the flame goes out.

Extension Cord Wire Size
Requirements

Up to 30.5 meters (100 feet) long, use 1.0
mm

2

(16 AWG) conductor

30.6 to 61 meters (101 to 200 feet) long, use
1.5 mm

2

(14 AWG) conductor

Push ON/OFF switch to ON (|) position and
heater should start in 5 seconds. If heater
does not start, see Troubleshooting (page 7).

TO STOP HEATER

1.

Push ON/OFF switch to OFF (O)
position.

TO RESET HEATER

1.

Push ON/OFF switch to OFF (O) posi-
tion and wait 10 seconds (2 minutes if
heater has been running).

2.

Repeat steps under To Start Heater.

Figure 4 - Cross Section Operational View

|

O

ON/OFF Switch

|

O

ON/OFF Switch

Clean
Heated
Air Out

Fuel
Filter

Air Line
To Burner

Air
Output
Filter

Air Pump

Air Intake
Filter

Cool
Air
In

Fan

Combustion Chamber

Ignitor

Motor

Ignition Control
Assembly

Air For Fuel System

Air For Combustion
And Heating

Fuel

Nozzle

Fuel
Tank