COMMUNICATION
3.29
ALARM YES
Alarm Reports
This prompt displays when the Path Type is Primary. All backup paths within the
group follow the same programming for Alarm Reports. Default is Yes.
NO YES FIRE
When YES is selected, the following reports are sent to the receiver for all zone
types:
• Alarm
• Bypass
• Reset
• Restore
When FIRE is selected, the following reports are sent for Fire, Fire Verify and
Supervisory Zones:
• Alarm
• Bypass
• Reset
• Restore
3.30
SPV/TRBL YES
Supervisory/Trouble Reports
This prompt displays when the Path Type is Primary. All backup paths within the
group follow the same programming for Supervisory/Trouble Reports. Default is Yes.
NO YES FIRE
When YES is selected, the following reports are sent for all zone types:
• Trouble
• Low Battery
• Missing
• Fault
• Restorals
• System Troubles
• System Restoral
When FIRE is selected, the following reports are sent for Fire, Fire Verify, and
Supervisory Zones:
• Trouble
• Low Battery
• Missing
• Fault
• Restorals
• System Troubles
• System Restoral
3.31
O/C USER NO YES
Opening/Closing and User Reports
This prompt displays when the Path Type is Primary. All backup paths within the
group follow the same programming for Opening/Closing and User Reports. Default
is Yes.
When YES is selected, the following reports by user are sent to this receiver.
• Opening
• Code changes (including adding, deleting, changing)
• Closing
• Schedule changes (temporary, permanent, shift)
• Bypass
• Holiday date changes
• Reset
3.32
DOOR ACS YES
Door Access Report
This prompt displays when the Path Type is Primary. All backup paths within the
group follow the same programming for Door Access Reports. Default is Deny.
NO YES DENY
Select YES to enable Door Access Granted and Denied reports to this receiver
whenever a door access is granted to a user. The Door Access Granted report is
only sent if the keypad number has also been selected in Access Keypads under the
SYSTEM REPORTS programming.
Select DENY to enable Door Access Denied reports only to this receiver when a door
access is denied to a user.
3.33
PANIC TST NO YES
Panic Test (XR500N/XR500E only)
YES allows the panic zone test verification and failure results to be sent to the
central station receiver. NO disables the panic test report. The default setting is
NO. The system test start, stop, panic zone verification, and panic zone failure
messages sent to the central station and the trips count operation are the same as
used under the Walk Test. See Using the Walk Test section in the Appendix.
3.33
SEND COMM TRBL:
Send Communication Trouble
NO
YES This prompt displays for each path and determines if and how communication
trouble on the path is sent to the receiver. A trouble message indicates both the
path number and communication type that failed. Default is Yes.
3.34
SEND PATH INFO:
Send Path Information
NO YES This prompt displays for each path and if YES, each panel message includes path
information such as path number, communication type, and path type. Default is No.