Feature upgrade, 1  feature upgrade, 1  encryption – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 70: 2  all no yes option, 3  service user authentication, 1 encryption, 2 all no yes option, 3 service user authentication, Stop, Set lockout code

XR500 Series Canadian Programming Guide
Digital Monitoring Products
61
STOP
SET LOCKOUT CODE
Stop
20.1
STOP
Stop
Save Programming
WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN
AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE
PROGRAMMING CHANGES.
At the STOP prompt, pressing any Select key allows you to exit the Programmer
function of the panel. When selected, the panel performs an internal reset and
exits the programmer.
The STOP routine causes the following conditions to occur:
• All 1100 Series DMP Wireless transmitters are reset to NORMAL
• The panel Status List is cleared
During the reset, all keypad displays are momentarily blank for two seconds. After
the reset, the programming function terminates and the keypads return to the status
list display.
The STOP prompt does not disarm the system. Any new areas or zones that were
added during programming are not armed until the system is disarmed and armed
again.
Missing LX-Bus™ Modules Displayed
The Programmer includes a feature following the STOP routine that displays the
name of any programmed LX-Bus module not currently connected to the panel. For
example, if you had enabled any LX-Bus options and not yet installed a 481 LX-Bus
Expansion Card, after the STOP routine the panel displays NO LXBUS CARD. This is a
helpful reminder to install the card. This feature can also be a troubleshooting tool
to indicate a problem if you installed the card and this message still displays. The
following list shows the different messages and their associated LX-Bus cards.
Keypad Display
Missing Card
NO LXBUS CARD
481 LX-Bus™ Expansion Card
NO PRINTER CARD
462P Printer Interface Card
NO HOST CARD
462N Network Interface Card
(with NETWORK communication selected)
The above messages clear automatically from the keypad after a few moments.
Power Up
When the XR500 Series Canadian panel is powered up after an AC power failure,
any zone transitions are not recognized for 120 seconds. Normal zone processing
resumes at the end of the 120 seconds.
Set Lockout Code
21.1
SET LOCKOUT CODE
Set Lockout Code
Pressing COMMAND at the STOP prompt displays SET LOCKOUT CODE. This allows
you to program a code that is then required to gain access to the panel internal
Programmer through the keypad. You can change this code at any time to any
combination of numbers from three to five digits long. You do not need to enter
leading zeros when using the lockout code. Initializing the panel does not clear a
Lockout Code. Lockout Codes can be changed through Remote Link.
Once you have changed the code, it is important to write it down somewhere and
store it in a safe place. Lost Lockout Codes require the panel to be sent back to
DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout
Code command.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.