XR500 Series Canadian Programming Guide
Digital Monitoring Products
49
ZONE INFORMATION
Zone Information
19.1
ZONE INFORMATION
Zone Information
Zone Information allows you to define the operation of each protection zone used in
the system. All protection zones, whether located on a command processor panel,
Security Command keypad, or zone expander are programmed the same way.
19.2
ZONE NO: -
Zone Number
Enter the number of the zone you intend to program. Available zone numbers are
shown in the table below. The keypad zone numbers begin with the keypad address
and are followed by the particular zone from that keypad. For example, a 7073 at
keypad address 7 would provide zones 71, 72, 73, and 74.
Press COMMAND to enter a zone name.
Address
Programming Zone Number
Panel
1-10
1
11-14
2
21-24
3
31-34
4
41-44
5
51-54
6
61-64
7
71-74
8
81-84
9
91-94
10
101-104
11
111-114
12
121-124
13
131-134
14
141-144
15
151-154
16
161-164
1100 Series Key Fob
400-449
LX-Bus 1 (A)
500-599
LX-Bus 2 (B)
600-699
LX-Bus 3 (C)
700-799
LX-Bus 4 (D)
800-899
LX-Bus 5 (E)
900-999
Note: For 1100 Series Key Fob zones (400-449), programming continues at the 1100
Series Key Fobs Section.
19.3
* UNUSED *
Zone Name
Zone names can have up to 32 alphanumeric characters. A name must be given to
each zone in the system. The name can display at the keypads during arming and
disarming so the user does not have to memorize zone numbers. Users can asso-
ciate a zone name with a particular protection point. A zone that is not part of the
system must be marked unused.
To add a zone name to the system, press any Select key and then enter up to 32
characters for the new zone name. Press COMMAND to continue.
To mark a zone unused, de lete the old name by pressing a top row Select key, then
press the COMMAND key. The pro grammer auto matically pro grams the name as
* UNUSED *. If you have already cleared Zone Information during Initialization, the
zones is marked * UNUSED *.