2.7 SERIAL

PORTS

The ACEs (Asynchronous Communication Elements ACE1 and ACE2) are used to convert the
parallel data to a serial format on the transmit side and convert the serial data to parallel on the
receiver side. The serial format, in order of transmission and reception, is a start bit, followed by
five to eight data bits, a parity bit (if programmed) and one, one and half (five-bit format only) or
two stop bits. The ACEs are capable of handling divisors of 1 to 65535, and produce a 16x clock
for driving the internal transmitter logic.

Provisions are also included to use this 16x clock to drive the receiver logic. Also included in the
ACE are a complete MODEM control capability, and a processor interrupt system that may be
software tailored to the computing time required to handle the communications link. The following
is a summary of each ACE accessible registers.

DLAB Port

Address

Register

Receiver buffer (RBR, read)

0

base + 0

Transmitter holding register (THR, write)

0

base + 1

Interrupt enable (IER)

X

base + 2

Interrupt identification (IIR, read only)

X

base + 3

Line control (LCR)

X

base + 4

MODEM control (MCR)

X

base + 5

Line status (LSR)

X

base + 6

MODEM status (MSR)

X

base + 7

Scratched register

1

base + 0

Divisor latch (least significant byte) (LS)

1

base + 1

Divisor latch (most significant byte) (MS)

Table 2-3 ACE Accessible Register

(1)

Receiver Buffer Register (RBR)

Bit 0-7: Received data byte (Read Only)

(2)

Transmitter Holding Register (THR)

Bit 0-7: Transmitter holding data byte (Write Only)

(3)

Interrupt Enable Register (IER)

Bit 0: Enable Received Data Available Interrupt (ERBFI)
Bit 1: Enable Transmitter Holding Empty Interrupt (ETBEI)
Bit 2: Enable Receiver Line Status Interrupt (ELSI)
Bit 3: Enable MODEM Status Interrupt (EDSSI)
Bit 4: Must be 0
Bit 5: Must be 0
Bit 6: Must be 0
Bit 7: Must be 0

(4)

Interrupt Identification Register (IIR)

Bit 0: “0” if Interrupt Pending
Bit 1: Interrupt ID Bit 0
Bit 2: Interrupt ID Bit 1
Bit 3: Must be 0
Bit 4: Must be 0
Bit 5: Must be 0
Bit 6: Must be 0
Bit 7: Must be 0