Installation

17

2.8 Jumper Settings

The PCI-6308‘s voltage output channels can be configured with
different voltage range. Each output channel and its corresponding
jumpers are listed below.

Table 2-2: Channel Jumper Settings

The output range is dependent on the D/A converter's reference
voltage source and output mode (Bipolar or Unipolar). JP11 and
JP12 are used for setting reference voltage sources from either
internal or external. External reference voltage input (ExtVref) is
located on connector CN1. JP1~8 and JP9/10 are used to set the
output mode to be unipolar or bipolar.

Channel NO.

Corresponding Jumper

For output mode

(Unipolar/Bipolar)

Corresponding Jumper For

reference voltage sources

(external/internal)

CH0

JP1

JP9

JP11

CH1

JP2

JP9

JP11

CH2

JP3

JP9

JP11

CH3

JP4

JP9

JP11

CH4

JP5

JP10

JP12

CH5

JP6

JP10

JP12

CH6

JP7

JP10

JP12

CH7

JP8

JP10

JP12