ADLINK ACL-8454/12 User Manual
Page 60

52
• Appendix B Timer/Counter Operation
Control Byte
Before loading or reading any of these individual counters, the control byte
(BASE+3) must be loaded first. The format of the control byte is:
Bit
7
6
5
4
3
2
1
0
SC1
SC0
RL1
RL0
M2 M1 M0
BCD
• SC1 & SC0 - Select Counter ( Bit7 & Bit 6)
SC1 SC0 COUNTER
0
0
Select Counter 0
0
1
Select Counter 1
1
0
Select Counter 2
1 1 ILLEGAL
• RL1 & RL0 - Select Read/Load operation ( Bit 5 & Bit 4)
RL1 RL0 OPERATION
0
0
COUNTER LATCH FOR STABLE READ
0 1 READ/LOAD
LSB
ONLY
1 0 READ/LOAD
MSB
ONLY
1
1
READ/LOAD LSB FIRST, THEN MSB
• M2, M1 & M0 - Select Operating Mode ( Bit 3, Bit 2, & Bit 1)
M2 M1 M0
MODE
0 0 0 0
0 0 1 1
x 1 0 2
x 1 1 3
1 0 0 4
1 0 1 5
• BCD - Select Binary/BCD Counting ( Bit 0)
0
16-BITS BINARY COUNTER
1
BINARY CODED DECIMAL (BCD) COUNTER (4
DIGITAL)
Note
The count of the binary counter is from 0 up to
65,535 and the count of the BCD counter is from
0 up to 9,999