ADLINK PCIe-2602 User Manual
Page 49
Function Library
39
PCIe-2602-FLR
The number of the SDI channel, with allowed values from 0
to 31.
Buffer
Image buffer pointer.
Return Value
No error occurs if return value ≥ 0; if a negative value, please refer
to Other Functions for return code error information.
Acquisition Status
Retrieves current acquisition status.
Syntax
C/C++
int Sdi_GetAcquisitionStatus (UINT Number,
UINT &Status)
C#
int GetAcquisitionStatus (uint Number, out
uint Status)
VB.Net
GetAcquisitionStatus (ByVal Number as UInte-
ger, ByRef Status as UInteger) As Integer
Parameter(s)
Number
The number of the SDI channel, with allowed values from 0
to 31.
Status
Acquisition status, from among:
0: Stopped
1: Running
Return Value
No error occurs if return value ≥ 0; if a negative value, please refer
to Other Functions for return code error information.