ADLINK ND-6063 User Manual
Page 71
Advertising

Command Set
• 63
Note : When you want to change the checksum or baud rate then the
DEFAULT* pin should be grounded at first.
@Example
User command:
%0130400600<CR>
Response:
!30<CR>
Item
Meaning
Description
%
(Leading Code)
Command leading code.
01
(OldAddr)
Original address ID is 01H.
30
(NewAddr)
New address ID is 30H
(Hexadecimal).
40
(TypeCode)
Digital I/O module.
06
(BaudRate)
Baud rate is 9600.
00
(CheckSumFlag)
00 means checksum is disable.
<CR>
Carriage return
0x0D.
Code
Baudrate
03
1200 bps
04
2400 bps
05
4800 bps
06
9600 bps
07
19200 bps
08
38400 bps
09
115200 bps
Table 0-1 Baud rate setting code
Table 0-2 Check sum flag setting
7
6
5
4
3
2
1
0
Reserved
Must to be 0
Checksum
0 : disable
1 : enable
Reserved
Must to be 000000
Advertising