Table 7-2 signals: cold reset procedure – ADLINK aTCA-N700 User Manual

Page 38

Advertising
background image

aTCA-RN710 User's Guide

38

„

Deactivate

Dea

c

tiva

te Done

De

ac

ti

va

te

CMD

Power OFF

Deactivate CMD

IPMC

LMP

UART#1

Power

Sequence

P5(4)

P5(5)

PAYLO

D

I

nterfac

e

Figure 7-3 Deactivate Procedure

⒮

Shelf manager sends Deactivate to IPMC.

①

IPMC sends Deactivate to LMP via PAYLOAD Interface (UART).

②

LMP completes the operation and sends the completion message via PAYLOAD Interface

(UART) to IPMC.
③

IPMC initiates Power Down sequence to power off Front Blade and RTM.

Table 7-3 Signals: Deactivate Procedure

Signal Name

Status

PAYLOAD Interface
P5(4),P5(5)

Deactivate Command

- IPMI Message

Deactivate Done Indicator

- IPMI Message

„

Activate

Figure 7-4 Activate Procedure

⒮

Shelf manager sends Active Command to IPMC.

①

IPMC initiates Power ON sequence to power ON Front Blade and RTM.

Table 7-4 Signals: Activate Procedure

Signal Name

Status

PAYLOAD Interface
P5(4),P5(5)

Activate Command

- IPMI Message

Deactivate Done Indicator

- IPMI Message

Advertising