ADLINK cPCI-3615 User Manual

Page 22

Advertising
background image

8

Specifications

1. Hard drive limits operational vibration. When application requires

higher vibration specification, it is recommended to use a flash disk.

2. ADLINK-certified thermal design. The thermal performance is

dependent on the chassis cooling design. Forced airflow with
3.2 m/s is required. Temperature limit of optional mass storage
devices may affect the thermal specification.

Faceplate I/O

4HP (cPCI-3615):
• 2x USB 2.0 ports
• 2x 10/100/1000BASE-T Ethernet ports
• Analog DB-15 VGA port
8HP (cPCI-3615D):
• 4x USB 2.0 ports
• 2x 10/100/1000BASE-T Ethernet ports
• Analog DB-15 VGA port
• DB-9 RS-232/422/485/485+ port
• PS/2 Keyboard/ Mouse combo port
• Line-in and Line-out ports
cPCI-R3610(T):
• 2x USB 2.0 ports
• 10/100/1000BASE-T Ethernet port
• 2x DB-9 RS-232 serial ports

OS
Compatibility

• Microsoft Windows XP Professional, x64 Edition
• Microsoft Windows Vista x64 Edition
• Microsoft Windows 7 x86 Edition
• Red Hat Enterprise Linux 5.3
• Fedora 12
• Other OS support upon request

Environmental

• Operating Temperature (with forced air flow)

2

:

- Standard: 0°C to 60°C
- Extended: -20°C to 70°C
- Extreme Extended temperature: -40°C to 85°C

• Storage Temperature: -40°C to 85°C
• Humidity: 90% @ 60°C non-condensing
• Shock: 15G peak-to-peak, 11ms duration, non-operating
• Vibration

1

: Operating 1.88Grms, 5-500Hz, each axis w/o HDD

EMI

• CE EN55022
• FCC Class A

Specifications are subject to change without prior notice.

Advertising