Parallel Port Interface

The parallel port supports standard parallel, Bi-directional, ECP, and EPP protocols. The SCH3114I-NU

chip (U15) provides the parallel port interface signals.

The parallel header provides 26 pins, 2 rows, odd/even sequence (1, 2), with 0.100" (2.54mm) pitch.

Note: The shaded table cells denote power or ground. The * symbol indicates the signal is Active Low.

Table 3-4. Parallel Interface Pin Signals (J16)

Pin # Signal

In/Out Description

1

Strobe*

Out

Strobe* – This is an output signal used to strobe data into the printer.
I/O pin in ECP/EPP mode.

2

AFD*

Out

Auto Feed* – This is a request signal into the printer to automatically
feed one line after each line is printed.

3

PD0

I/O

Parallel Port Data 0 – These pins (PD0 to PD7) provide parallel port
data.

4

ERR*

Out

Error* – This is a status output signal from the printer. A Low State
indicates an error condition on the printer.

5

PD1

I/O

Parallel Port Data 1 – Refer to pin 3 for more information.

6

INIT*

Out

Initialize* – This signal used to Initialize printer. Output in standard
Mode, I/O in ECP/EPP mode.

7

PD2

I/O

Parallel Port Data 2 – Refer to pin 3 for more information.

8

SLIN

Out

Select In – This output signal is used to select the printer. I/O pin in
ECP/EPP mode.

9

PD3

I/O

Parallel Port Data 3 – Refer to pin 3 for more information.

10,
12

GND

Ground

11

PD4

I/O

Parallel Port Data 4 – Refer to pin 3 for more information.

13

PD5

I/O

Parallel Port Data 5 – Refer to pin 3 for more information.

14,
16

GND

Ground

15

PD6

I/O

Parallel Port Data 6 – Refer to pin 3 for more information.

17

PD7

I/O

Parallel Port Data 7 – Refer to pin 3 for more information.

18,
20

GND

Ground

19

ACK*

In

Acknowledge* – This printer output status indicates it has received
the data and is ready to accept new data if the signal state is Low.

21

BUSY

In

Busy – This printer output status indicates the printer is not ready to
accept data if the signal state is High.

22,
24

GND

Ground

23

PE

In

Paper End – The printer output status indicates the printer is out of
paper if the signal state is High.

25

SLCT

In

Select – This printer output status indicates the printer is selected and
powered on if the signal state is High.