manually prime the auger.

The room fan button will override the # 1 heat level setting fan speed and go to high speed. This will not
change the fan speed on the #2 - #5 heat level settings.

The auger trim button allows for a low/high fuel setting fine tune adjustment on the all 5 settings. When
pushing the auger trim button select either the heat level up button or heat level down button depending on the
fine tune requirements.

The draft trim allows for a low/high setting fan speed and go to a lower or
higher setting depending on requirements. When pushing the draft trim
button select either the heat level up button or the heat level down button
to fine tune fan speed.

The heat level setting button is a manual heat adjustment. Pushing the
heat level setting button will advance the heat settings one level each time
that it is pushed. The LED light will show which heat level setting the
unit is on. At start up, regardless of where the heat level setting button is
set, the unit will feed on the pre-set heat level setting. Once the start up
sequence has been established, the fuel feed rate setting will run at
whatever fuel level setting you selected.

During a short power outage, the board will detect if the proof of fire
switch is engaged. If it is still engaged (closed) the unit will auto re-start.

Shutdown
To shut the unit down, simply press the On/Off button. The
room fan and exhaust blower will continue to operate until the
low limit/cool down sensor tells it that the fire is out. At that
point the exhaust fan will continue to run for an additional 15
minutes to make sure there is no exhaust in stove.


Your control panel comes with the ability to use ten (10) separate programming features. This programming
must be done by a qualified factory trained technician. Contact your local dealer to set up an appointment to

have this done. The unit also has three (3) separate modes of operation (switch located on top of board). The

manual setting allows the operator to choose heat level setting changes. The T-STAT setting allows the

operator to set the high heat level setting and when the thermostat is satisfied, the unit will automatically go to

the low heat level setting. The AUTO setting allows the unit to shut completely off when the thermostat is

satisfied and re-start when the thermostat calls for heat. This setting can only be used with wood pellets.