CHANGE HEAT LEVEL (thermostat inactive)

• If the operator makes a change to the heat level while the stove is inactive, the stove will move to that

level. The next time the thermostat calls for heat, the most recently programmed heat level will
become the Thermostat Heat Level and the stove will operate at that point until the thermostat no
longer calls for heat.

FIGURE 9: HARVESTER COMBUSTION FRESH AIR CONTROL

COMBUSTION FRESH AIR CONTROL
Combustion fresh air can be controlled on the Harvester. This optional control assists in optimizing the burn
rate of different corn fuels. All air entering the firebox is controlled by the fresh air control system. To ensure
no air leakage or air infiltration into your home when the Harvester Stove is not in use; the combustion air
control lever should be kept in its closed position.

REAR VIEW

The newer HR-01 models
have the 3” air shutter on the
back of the unit for adjusting
the fresh air. Connect your
fresh air from outside to the
back of the stove for optimal
performance.

When starting the appliance
have the air shutter about ¼
open and then open it app.
1/3 to half open for full burn.
Opening the shutter wide
open might trip the vacuum
sensor if the home or the unit
venting system is not
balanced correctly.