Command quick reference, Command set for the ppla – AMT Datasouth Fastmark 400 User Manual
Page 27

User's Guide 26
COMMAND QUICK REFERENCE
This section lists all software commands of the printer.
Command Set for the PPLA
System Setting Commands
These commands will cause related parameters to be saved in the non-volatile memory. These
parameters will be stored unless other commands or a front panel reset changes them.
Command
Description
Parameter
Factory default
<STX>KI4n
Media empty check
n : 0 - disable,
1 - enable.
1
<STX>KI5nn Set gap length
nn: 01 to 10 (mm)
1
<STX>KI7n
Set transfer type
n : 0 - direct thermal,
1 - thermal transfer.
1
<STX>KI8n
Set baud rate
n : 0 - 9600,
1 - 2400, 2 - 2400,
3 - 19200, 4 - 4800,
5 - 38400, 6 - 2400,
7 - 9600 baud.
0
<STX>KI;n
Set standard control
code.
Set alternative control
code.
n: 1 - Standard control
code
2 - alternate control
code
1
<STX>KI<m Set symbol set for ASD
smooth font set
m : 0 - USASCII,
1 - United Kingdom,
2 - Spanish,
3 - Swedish,
4 - French,
5 - German,
6 - Italian,
7 - Danish/Norwegian.
0
Note: <STX>KI7n command is ignored by model FM402DT