UM-CV-751-MCS-Q114V1 www.austin-hughes.com
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x06, 0x4D,0x43
0x23
OSDB
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
•
Set OSD Button
• Function
The computer switches the OSD button function ON /OFF
OSDB :
The OSD membrane button control code for the LCD display
0x00
OFF
0x01
ON
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x06
0x23
OSDB
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
• Ack
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x15
0x23
ERR
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A