21 > pip control – Austin Hughes MCS User Manual

Page 27

Advertising
background image

UM-CV-751-MCS-Q114V1 www.austin-hughes.com

Header

Command

ID

Val 1

Val 2

Val 3

Val 4

Val 5

Val 6

Checksum

Footer

0x06, 0x4D,0x43

0x50

PIP

0x00

0x00

0x00

0x00

0x00

0x0D, 0x0A

Set PIP Control

• Function

The computer turns the PIP function of the LCD display.

The PIP function may or not be available on a particular LCD display depending on the model selected

Header

Command

ID

Val 1

Val 2

Val 3

Val 4

Val 5

Val 6

Checksum

Footer

0x4D, 0x43,0x06

0x50

PIP

0x00

0x00

0x00

0x00

0x00

0x0D, 0x0A

• Ack

PIP :

The PIP function code for the LCD display

0x10

PIP OFF

0x11

Small

0x12

Large

0x13

Side by side

Header

Command

ID

Val 1

Val 2

Val 3

Val 4

Val 5

Val 6

Checksum

Footer

0x4D, 0x43,0x15

0x50

ERR

0x00

0x00

0x00

0x00

0x00

0x0D, 0x0A

• Nak

< 2.21 > PIP Control

P.25

Advertising