24 > pip location control – Austin Hughes MCS User Manual
Page 31

UM-CV-751-MCS-Q114V1 www.austin-hughes.com
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x06, 0x4D,0x43
0x53
P.Loc
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
•
Set PIP location
• Function
The computer adjusts the PIP position of the display
The PIP function may or not be available on a particular LCD display depending on the model selected
Available only when the PIP is in small or large size state
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x06
0x53
P.Loc
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
• Ack
P.Loc :
The PIP location code for the LCD display
0x10
Upper Left
0x11
Upper Right
0x12
Lower Left
0x13
Lower Right
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x15
0x53
ERR
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
• Nak
< 2.24 > PIP Location Control
P.29