CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

ShOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

WARNING: Do not oper-

ate an unvented gas log set in

this fireplace with the chimney

removed.

Figure 29 - Gas Line Knockout

Side
Firebrick
Finished
Side

Refractory
Knockout
Plug

Outside of
Fireplace

Gas Line
Conduit
Insulation

Gas
Conduit
Cover

1/2" Dowel

Remove
Knockout

oPTional gas line

insTallaTion

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

NOTICE: Before you proceed, make sure your
gas supply is turned off.
A gas line may be installed for the purpose
of installing a vented or vent-free decorative
gas appliance available through your local
distributor. Use only gas piping approved
by local codes. When installing a gas line, a
shutoff valve designed for installation outside
the appliance is recommended.
The gas pipe is intended for connection to
a decorative gas appliance that operates
using natural or propane/LP gas only. This
appliance must have an automatic shutoff
device and must comply with the Standard
for Decorative Gas Appliances for Installa-
tion in Vented Fireplace, ANSI Z21.60-1990
.
ONLY UNVENTED GAS LOG SETS WHICH
HAVE BEEN FOUND TO COMPLY WITH
THE STANDARD FOR UNVENTED ROOM
HEATERS, ANSI/IAS/AGA Z21.11.2, ARE TO
BE INSTALLED IN THIS FIREPLACE.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refrac-

tory or firebrick wall located approximately
2" above refractory hearth floor. Knockout
indentation must be firmly tapped with any
solid object such as a 1/2" dowel until it is
released. Remove fragmented portions of
refractory (see Figure 29).

2. Remove gas line cover plate located on

rear of fireplace and pull out insulation
from gas line conduit sleeve. Save insula-
tion for reuse.

3. Run gas line into fireplace through the rear

at 11

1

/

4

" from floor and through gas line

conduit sleeve (if using a raised platform,
add height). Provide sufficient gas line into
fireplace chamber for fitting connection
(see Figure 30). Note: Secure incoming
gas line to wood framing to provide rigidity
for threaded end.

4. Repack insulation around gas line and into

sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install gas appliance or cap off
gas line if desired.

Seal
Opening
with
Refractory
Cement

Outside of
Fireplace

Gas
Line
Conduit

Repack
Insulation

Incoming
1/2" Black
Iron Pipe

Side
Firebrick
Finished
Side

Provide Enough Threaded
End for Fitting Connection

Figure 30 - Gas Line Installation