Venting installation – Desa (V)PN36-A User Manual

Page 9

Advertising
background image

www.desatech.com

115607-01C

9

Maximum

Height

Chase

Termination

50 Ft.

Minimum

Height

15 Ft.

VenTing insTallaTion

Continued

Figure 19 - Firestop Spacer with Living

Space Above Ceiling

Figure 20 - Firestop Spacer with Attic

Space Above Ceiling

Existing
Ceiling
Frame

Firestop
Spacer

Screws or
Staples
(Min. of 8)

Firestop
Spacer

Screws or Staples
(Min. of 8)

Existing
Ceiling
Frame

Figure 21 - 10 Foot Rule

10 FOOT RULE

All chimney terminations must extend a mini-
mum of 3 feet above the highest point where it
passes through the roof and must be at least 2
feet above roof with a 10 foot horizontal span
(see Figure 21).
IMPORTANT: If an exposed portion of chim-
ney is greater than 4 feet above the roofline,
use support wires to keep chimney secure.
Support wires may be attached to outer pipe
of chimney with screws, if screws do not
penetrate inner flue pipe.

Figure 22 - Maximum Chimney Height

Storm
Collar

Flashing

Firestop
Spacer

RTL-12D

RTL-12D STL-12D

MINIMUM / MAxIMUM ChIMNEY
HEIGHT

The minimum height of the chimney (mea-
sured from the base of the fireplace to the flue
gas outlet-end of pipe) is 16 feet for a straight
run, 16 feet minimum for a run with 1 elbow set
and 25 feet minimum for a run with 2 elbow
sets. (A set consists of one starter elbow and
one return elbow.)

Uncommon circumstances such as neigh-
boring hills, tall trees, or strong wind areas
can cause down drafts in chimney system.
In such cases, going beyond the minimum
recommended height would be preferable to
provide a better draw.
The fireplace height approved for any chim-
ney run with this fireplace system is 40 feet
measured from bottom of fireplace to flue
outlet-end of pipe (see Figure 22).

WARNING: Do not oper-

ate an unvented gas log set in

this fireplace with the chimney

removed.