224

Programming Reference

VERSAJET

US h

[Name]

Get system information

[Format]

ASCII

US h

Hex

1F 68

Decimal

31 104

[Return value]

Function

Length (Byte)

Value

Start byte

1

0x5F

Customer name

32

0x20~0x7E

Model name

32

0x20~0x7E

Firmware version

16

0x20~0x7E

End byte

1

0x00

[Description]

Get system information.


[Notes]
This is a real-time command that the printer executes upon receiving it.

The printer returns 82 bytes, the first and last bytes are fixed values. Make sure the host

computer can receive data from receiving buffer.

The return value of customer name is a fixed length of 32 bytes, filled with char

0x00(Null) for remaining bytes if the length of real data is smaller than 32.

The return value of model name is a fixed length of 32 bytes, filled with char 0x00(Null)

for remaining bytes if the length of real data is smaller than 32.

The return value of firmware version is a fixed length of 16 bytes, filled with char

0x00(Null) for remaining bytes if the length of real data is smaller than 16.