Datamax E-4203 User Manual

Page 34

Advertising
background image

24

E-4203/E-4204/E-4304

9) CONTROL CODES

Allows code selection listed in
Programmer’s manual.

Possible Values:

*

(

STD) Standard Codes

(ALT) Alternate Codes

10) CONT FORM LENGTH

Sets the page (label) size when the
‘SENSOR TYPE’ is set to continuous
media.

Possible Values:

Range: 0 – 9999; default = *100
(Units = .01 inch)

11) OOS MAXVOLT

Sets the media sensor level for the
Out Of Stock condition.

Possible Values:

Range: 0 – 16; default = *2
(Units = .1 volt)

12) TOF GAIN

Sets media sensor Top of Form gain
value.

Possible Values:

Range: 0 – 15; default = *10

13) TOF DELTA

Sets the minimum media sensor
change required to signify a label
gap or mark.

Possible Values:

Range: 0 – 50; default = *10
(Units = .1 volt)

14) TOF LOW

Sets the minimum media sensor reading
for paper (gap/notch) or mark
(reflective).

Possible Values:

Range: 0 – 50; default = *0
(Units = 0.1 volt)

15) LABEL WIDTH

Sets the label width.

Possible Values:

Range: 75 – 410; default = *410
(Units = .01 inch)

16) SCALABLE FONT

Sets the number of memory blocks to
allocate for scalable fonts.

Possible Values:

Range: 0 – 128; default = *64
(Units = 4K Bytes)

17) INTERNAL MODULE

Sets the number of memory blocks to
allocate for the internal RAM
module.

Possible Values:

Range: 0 – 128; default

[1]

= *128

(Units = 4K Bytes)

[1]

The E-4304 has a default value of 64.

18) LABEL ALIGNMENT

Sets the label alignment method

(see

Section 4.5)

.

Possible Values:

YES (user manually determines

‘ALIGN LENGTH’)

AUTO (printer determines ‘ALIGN

LENGTH’)

* NO (no Label Alignment used)

Advertising