15. Wire the wall switch supplied with the Da- Lift. See Figure 17.

16. A control panel may be connected to the Da-Lift by using the

wall switch wire leads. The control panel must provide a
momentary, dry contact closure of at least 1/2 second.

a. Use 3-conductor 20-24 AWG wire to connect the control

panel to the wall switch leads. See Figure 17.

b. A momentary closure across the white and red wires will be

an “up” command.

c. A momentary closure across the white and black wires will

be a “down” command.

d. A momentary closure across the white, red, and black wires

will be a “stop” command.

CAUTION: Never apply voltage to the wall switch leads or the
Da-Lift will be damaged.

ATTENTION: N'appliquez jamais une tension aux fils du
commutateur mural sinon le Da-Lift sera endommagé.

Procedure (Continued)

Figure 17

Figure 18

Recommended Wire Size: 20-24 AWG

White Wire

Black Wire

Red Wire

Up

Stop

Down

White Wires

Receiver Cable

Control Box

To IR or RF
Receiver

Port Labeled "Eye"

Cover

Black Wires

Red Wires

17. Optional Infrared (IR) or Radio Frequency (RF) remote controls

are available. To install either remote, remove the Covers from
the Control Box. Route the eceiver Cable through the Da-Lift and
plastic bushing of the Control Box. Plug the Receiver Cable into
the motor control board port labeled “EYE”. See Figure 18.
Plug IR or RF receiver into other end of Receiver Cable.
“Learn” the RF remote and receiver by following the
directions supplied with the RF.