Target position, Actual position – Delta MMC120 User Manual

Page 123

Advertising
background image

123

TARGET POSITION

When the axis is in

Closed Loop Mode

, the TARGET POSITION is the calculated

instantaneous ideal position for the axis. The TARGET POSITION is calculated every

loop by the

target generator

state machine of the on-board motion control program. The

PID

routine uses the difference between the TARGET POSITION and the

ACTUAL

POSITION

as its input to compute any required corrective drive.

During a move the transition of the TARGET POSITION toward the

COMMAND

POSITION

will be the perfect profile for the

ACTUAL POSITION

to follow.

NOTE: When an axis is stopped, the TARGET POSITION should be the same as the

COMMAND POSITION

unless an error or HALT has occurred (see

STATUS

).

NOTE: When an axis is not in position Closed Loop Mode, TARGET POSITION is

set to the ACTUAL POSITION.

Why Bother?

Knowing the relationship between the TARGET POSITION and

ACTUAL POSITION

is

key to tuning the axis. The main goal in tuning the axis is to minimize the error between

the TARGET and

ACTUAL POSITIONS

. The plot function is a very nice visual aid in

tuning the axis.

ACTUAL POSITION

The ACTUAL POSITION is the measured position of the axis at any moment. This

position is updated every loop. The ACTUAL POSITION is calculated from the

TRANSDUCER COUNTS

as follows:

ACTUAL POSITION =

TRANSDUCER COUNTS x SCALE

+ OFFSET

32768

Why Bother?

Before applying drive or hydraulic power, make sure the target position is set to the

actual position using a

‘ P’ command. Otherwise axis will jump to the TARGET

POSITION.

See

TARGET POSITION

.

Advertising