50 hour, Tractor, Rt100 powershift operator’s manual – Ditch Witch RT100 User Manual
Page 119

Service - 118
RT100 Powershift Operator’s Manual
50 Hour
50 Hour
Tractor
Check Drive Belt
Check belt every 50 hours for damage or wear.
Replace worn belt. Belt is properly tensioned
when long span (2) moves about 1/2" (13 mm)
when pushed. If needed, loosen alternator bolts
(1) and adjust idler pulley.
Check Hydraulic Reservoir Breather
Check hydraulic reservoir breather every 50
hours. Ensure breather is not clogged. Remove
dust around breather as needed by blowing with
low-pressure air. When breather element
becomes clogged, remove and clean or replace.
Location
Task
Notes
TRACTOR
Check drive belt
Check hydraulic reservoir breather
Check fuel tank breather
Check cab air filter
Change transmission fluid and filter (initial)
TRENCHER
Lube attachment driveshaft u-joints
EPG