Owner’s manual, Inspecting burners – Desa VS30PRA User Manual

Page 17

Advertising
background image

17

104417

OWNER’S MANUAL

Figure 25 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 26 - Incorrect Pilot Flame Pattern

WARNING: If yellow tipping

occurs, your heater could pro-
duce increased levels of carbon
monoxide. If front burner flame
pattern shows yellow tipping,
follow instructions at bottom of
this page. Yellow flame on rear
burner is normal.

Figure 28 - Incorrect Front Burner Flame
Pattern

Figure 27 - Correct Front Burner Flame
Pattern

Yellow Tipping At Top
of Blue Flame

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 25 shows a correct pilot flame pat-
tern. Figure 26 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 26

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 19 through 21

FRONT BURNER FLAME
PATTERN

Figure 27 shows correct front burner flame
pattern. Figure 28 shows incorrect front
burner flame pattern. The incorrect burner
flame pattern shows yellow tipping at top of
blue flame.

NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles are burned
by heater, causing brief patches
of orange flame.

If front burner flame pattern is incorrect, as
shown in Figure 28

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 19 through 21

Pilot Burner