Owner’s manual, Installation, Continued – Desa VS30PRA User Manual

Page 9: Floor clearances, Mantel clearances, Determining minimum mantel clearance

Advertising
background image

9

104417

OWNER’S MANUAL

14"
Min.

Combustible
Material

Noncombustible
Material

Hearth

5"
Min.

Combustible
Material

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

Figure 6 - Minimum Mantel Clearances Without Using Hood

Figure 7 - Minimum Mantel Clearances When Using Hood

Continued

Hearth

Combustible
Material

5"
Min.

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).

B. If combustible materials are less than

14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet clearances
listed in Figure 6 you will need a hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel
Clearance When Using a Hood

If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.

INSTALLATION

Continued

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

12"

8"

(A)

18"

14"

20"

16

3/4

"

22"

18

1/2

"

24"

20"

All minimum
distances are
in inches

Log Set
24"/30" Models

18" Model

2

1

/2

"

6"

8"

10"

Mantel Shelf

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Sets

18", 24",
& 30" Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

Hood
(GA6050, GA6052,
or GA6053)