Echelon Neuron User Manual
Page 135

Neuron Tools Errors Guide
127
NEX#
Description
11
Attempt to read from an unopened file. [NEX#11]
This is an internal error condition; please contact LonSupport.
12
Reading from file '<file>' (read behind end of file) [NEX#12]
Reading from file failed (read behind end of file). This is an internal error
condition; please contact LonSupport.
13
Unexpected EOF in file '<file>' at line #<line> [NEX#13]
Unexpected end of file. See error message for details. Attempt fix-up with
rebuild.
14
Line # <line> in input file '<file>' is too long [NEX#14]
A record in an input file was longer than expected. See error message for
details. Attempt fix-up with rebuild.
15
Line # <line> in input file '<file>' is invalid [NEX#15]
A record in an input file is invalid. See error message for details. Attempt
fix-up with rebuild.
16
Line # <line> in input file '<file>', byte count is invalid [NEX#16]
A record in an input file is invalid due to an incorrect byte count. See error
message for details. Attempt fix-up with rebuild.
17
Line # <line> in input file '<file>', checksum is invalid [NEX#17]
A record in an input file is invalid, bad checksum. See error message for
details. Attempt fix-up with rebuild.
18
System image symbol table '<file>' is invalid: symbol '<symbol>' not defined
[NEX#18]
Missing a required symbol from the system image's symbol table. See error
message for details. Does the chosen system image support the desired
memory configuration? Change the firmware version and image file to the
default and perform an unconditional build.
19
Specified transceiver type has invalid clock/bit rate combination [NEX#19]
Specified transceiver type has invalid clock/bit rate combination. Verify
that your hardware clock rate and transceiver preferences are correct.
20
Device's input clock is below minimum allowed for channel [NEX#20]
Device’s input clock is below the minimum allowed for the desired channel.
Choose a different transceiver or a faster clock rate.