Echelon FTXL User Manual
Page 245
FTXL User’s Guide
233
LID#
Description
21
The xif32bin.exe utility returned an error, indicating failure when
converting XIF to XFB
The binary device interface file (.xfb extension) could not be created.
Make sure a previously existing binary device interface file is not
write-protected. Also make sure the XIF32Bin.exe utility, which is
used to create the binary device interface file, is available in a folder
that is part of the system or current user search path. By default, the
utility can be found in your LONWORKS Bin folder.
22
An error occurred when reading a type info file (.NCT)
This is an internal error, possibly resulting from an earlier failure.
The .nct file is an intermediate file used by the ShortStack Wizard.
Re-run the LonTalk Interface Developer utility in Trace verbosity
mode and carefully examine the LonTalk Interface Developer utility
Summary window to determine the root cause of the failure.
23
An error occurred when reading a type info file (.NCT)
This is an internal error, possibly resulting from an earlier failure.
The .nct file is an intermediate file used by the ShortStack Wizard.
Re-run the LonTalk Interface Developer utility in Trace verbosity
mode and carefully examine the LonTalk Interface Developer utility
Summary window to determine the root cause of the failure. This
error is similar to LID#22, but refers to different internal software
components.
24
Type info (.NCT) file seems corrupted
This is an internal error, possibly resulting from an earlier failure.
The .nct file is an intermediate file used by the LonTalk Interface
Developer utility. Re-run the LonTalk Interface Developer utility in
Trace verbosity mode and carefully examine the LonTalk Interface
Developer utility Summary window to determine the root cause of
the failure.
25
Unexpected end of type info file (.NCT)
This is an internal error, possibly resulting from an earlier failure.
The .nct file is an intermediate file used by the LonTalk Interface
Developer utility. Re-run the LonTalk Interface Developer utility in
Trace verbosity mode and carefully examine the LonTalk Interface
Developer utility Summary window to determine the root cause of
the failure.
26
Error code not in use.
27
Unexpected file I/O error when reading a file
Refer to the error message for details of the failure cause.