Carefully bend the leads of IC1, IC2,
IC3 and Q2 on the heat sink at right
angles with pliers.

Install IC1, IC2 and Q2 in the positions
shown in Figure E. Fasten in place
using the parts shown in Figure F.
Spread the silicon grease on the back
of the transistor and ICs.

r IC1 - LM-317 IC

r IC2 - LM-337 IC

r Q2 - 2N6124 Transistor

Install IC3 as shown in Figure Fa.
r IC3 - LM-7805 IC
r Mount the fuse holder to the top hole in the back of the chassis,

with the side lug up, as shown in Figure G. Fasten in place with
the 3/8” nut. After the holder is secure, unscrew the top and insert
the fuse.

r Separate the wires of the line cord 3” from the end. Strip the

insulation off the end of all two end wires to expose 1/4” of bare wire.

r Insert 6” of the line cord into the bottom hole on the back of

the chassis, as shown in Figure G. Place the line cord into
the slot of the strain relief and squeeze the two sections
together with pliers. Then, insert the strain relief into the
hole.

r Install the transformer with the black wires side as shown

in Figure I. Use an 8-32 x 3/8” screw, #8 lockwasher and
an 8-32 nut on each side to fasten in place, as shown in
Figure H.

-8-

Figure E

Figure H

8-32 Nut

#8 Lockwasher

8-32 x 3/8” Screw

Figure F

Small 6-32 Nut

IC1, IC2,

Q2

Heat Sink

Insulator Washer

6-32 x 3/8”

Screw

LM7805

LM-337

LM-317

2N6124

Silicon Grease

Mica

Figure Fa

Figure G

Side Lug

Pliers

Mica

Small 6-32 Nut

IC3

LM7805

Heat Sink

Insulator Washer

6-32 x 3/8” Screw

Insulator Washer

Ribbed

Smooth

1/4”

Heatsink