OPERATING
HEATER

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position (see Figure 16).

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

5.

Turn control knob counterclockwise

C-clockwise

to the PILOT position.

Press in control knob for five (5) sec-
onds (see Figure 16).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 14 through
16. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
, page 12.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

If control knob does not pop up when
released, contact a qualified service
person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps

3 through 7. This heater has a safety
interlock system. Wait one (1) minute
before lighting pilot again.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Figure 16 - Control Knob In The OFF
Position

IGNITOR

PILOT

LO

OFF

HI

Control Knob

Ignitor Button

8.

Turn control knob counterclockwise

C-clockwise

to desired heating level. The

main burner should light. Set control
knob to any heat level between HI
and LO.

Figure 17 - Pilot

Pilot Burner

Ignitor Electrode

Thermocouple

CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Continued